FUNCTIONS FOR UP-AND-OVER DOOR OPENING - Dip Switch B n°1=ON
Description
AUTOMATIC / SEMI-AUTOMATIC
Automatic Cycle: with one pulse from the open command the door opens and stops in Dwell
mode for the time pre-set on the Dwell Trimmer. When this time expires the door automatically
closes
Semi-automatic Cycle: with one pulse from the open command the door opens and stays
stopped. To close the door, a close pulse is needed.
RE-CLOSING AFTER PASSAGE BETWEEN THE PHOTOCELLS: in opening and dwell cycles
(DIP-A No. 3 = ON
This function allows automatic re-closing of the door 3 seconds after passing between
the photocells.
DSA: PHOTOCELL AUTOMATIC CONTROL:
For the DSA control (Device for Safety Auto-test) it is necessary
to connect only the photocell transmitters (TX) to this output
and to select Dip-B No.4=ON: if this function is enabled, ELPRO
X and ELPRO XE will check that all the connected photocell
devices are cleared from obstacles and properly working before
starting any door movements, otherwise the door is not started.
DEADMAN FUNCTION:
The open/close operations are achieved by " holding on a command switched" (the relay is
not self-retaining) and consequently the user must be actively present during all automation
movements until the push-button or the key-switch is released.
INSTALLATIONS WITH VERY HIGH FREQUENCY OF USE:
This is a function for intense use with frequent inversions of direction: when this function is
enabled it takes into account the remaining motor run time when there is an inversion of
direction or passage between the photocells.
OPENING THROUGH EXTERNAL CLOCK:
Connection: connect the Clock NO contact in parallel
with OPEN terminal No. 4 and COMMON No. 3, activating
automatic re-closure with Dip-Switch No. 3=ON.
Operation: program the opening time on the clock.
When this present time comes up the gate will open and
remain open (the flashing light turns off) and will not
accept any other command (not even radio
commands) until the time set on the clock expires. When
this time expires the gate automatically closes after the
pause time.
XE
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
15
24V ac output for
photocell TX assigned
to the DSA control
External clock
3 4
NO
Dip-Switches and LED signals of the various functions
DIP-SWITCH-A N°3:
ON: Closes automatically
OFF: Semi-automatic
3
Dwell Trimmer: adjusts pause time for
Automatic mode from 1s up to 220 s
DIP-SWITCH-A N°11:
ON: Automatic re-closure after passage
between the pair of photocell after 3 seconds
11
OFF: No automatic re-closure
DIP-SWITCH-B N°4:
16
ON: Activates the DSA safety control
OFF: Deactivates the DSA safety control
4
DIP-SWITCH-B N°2:
ON: Activates the deadman mode
OFF: Deactivates the deadman mode
2
DIP-SWITCH-A N°12:
ON: Run Time memory enabled
OFF: No memory enabled
12
DIP-SWITCH-A N°3:
ON: Closes automatically
3
Important: use only and always
with Dip-switch A No.3 = ON
page 21