Télécharger Imprimer la page

fadini Elpro X Notice D'instructions page 13

Masquer les pouces Voir aussi pour Elpro X:

Publicité

Les langues disponibles

Les langues disponibles

GB
X
FOR SLIDING GATES WITH LIMIT SWITCHES:
position Dip Switch B No1= ON
Dip-Switch A
1 = ON Photocells stop during opening
2 = ON Radio does not reverse during opening
3 = ON Automatic closure
4 = ON Pre-flashing operational
5 = ON Step-by-step radio
6 = ON Pedestrian service
Dip-Switch B
1 = ON SLIDING GATE OPENER mode
2 = ON Deadman mode
3 = blank
4 = ON DSA photocell transmitter control if connected to dedicated terminals
ELECTRICAL CONNECTIONS TO TERMINALS FOR SLIDING GATE OPENING – Dip Switch B No. 1 = ON
Accessory
Safety edge:
Photocells:
Key-operated
switch:
Radio Contact:
(step-by-step mode)
Limit switches:
XE
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
7 = ON No function
8 = see SAFETY EDGE connections
9 = see SAFETY EDGE connections
10 = ON Flashing light off during pause
11 = ON Closes during Opening and during pause after passage on the
Photocells
12 = Blank
Electrical connections
1 2
NC contact for safety edge to allow travel reversing for a short
bit in both cycles and gate stopping: with DIP A No. 9=ON.
NOTE: if no safety edge is present it is not necessary to
bridge the contact input.
1 2
All NC contacts of
safety accessories
such as Photocells
NC
(receivers) must be
connected in series
NC
with terminals 1 and 2
NO and NC contacts to connect to
3 4 5 6
the respective terminals on the
selector switches or the push-button
panel.
NC
All possible configurations are
attached to the related control
accessories.
connecting any NO contact across the two
terminals generates, with each impulse:
3
7
- Opening only: Dip 2=ON and Dip 5 = OFF
- inversion of direction with each impulse
Dip 2 = OFF and Dip 5 = OFF
- Step-by-step: Open-Stop-Close-Stop
Dip 2 = OFF and Dip 5 = ON
- During opening no new command is
accepted. During dwell or closing, each new
command stops and reverses travel
direction.Dip 2=ON and Dip 5=ON
8 9 10
IMPORTANT: if the limit switches are
not used then bridge inputs 8 - 9 - 10
DIP-SWITCH-A No.9 = OFF
12 13
24V ac output max. load:
n°1 radio receiver
n°2 pairs photocells
DIP-SWITCH - B
ON
OFF
2 3 4
1
DIP-SWITCH - A
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - B
ON
OFF
1 2 3 4
Dip-Switches and LED signals of the various functions
DIP-SWITCH-A N°8 and N°9:
ON: Increase time during inversion
OFF: No increase of inversion time
8
ON: Inversion of direction with safety edge
OFF: No inversion of direction
9
L2 On = no obstacle detected, turns off in
case of obstacle
DIP-SWITCH-A N° 1:
ON: stop in Opening and reverse in
Closing once cleared from obstacle
OFF: no stop in opening, reverse on closing in
1
case of obstacle
L3 ON= no obstacle. It switches off in case
of obstacle
L4 OFF= no OPEN contact, turns on with
every open impulse
L5 OFF= no CLOSE contact, turns on with
every close impulse
L6 ON= STOP contact closed, turns off with
every stop impulse
DIP-SWITCH-A N°2 and N°5:
ON: no stop and no reversing in opening
2
OFF: during opening always stop and reverse
ON:Step-by-step with intermediate stop
OFF: reverse movement by every radio impulse
5
L7 OFF= no RADIO contact, turns on with
every radio contact impulse
L8 ON= off when gate closed
L9 ON= off with gate open