OPERATION
Controls
The hood is operated using the slide controls
under the bottom of the hood.
The light switch turns the lamps on and off.
The blower switch :makes it possible to
select the motor operating speed. Position 0:
motor off.
The pilot lamp lights up whenever the blower
is on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
LIGHT BULBS
This range hood requires two 13 watt
G24q-1 Compact Fluorescent lamps
(included).
ALWAYS
SWITCH
ELECTRICITY
SUPPLY
CARRYING OUT ANY
ON THE APPLIANCE.
To change bulbs:
1. Remove the screw securing the light lens.
Fig.12
2. Pull down lens to remove.
3. To replace lamp, grasp lamp at base and
pull out to remove. Fig.13
Replace with 13W Fluorescent lamp
noted above. CAUTION: BULB MAY BE
HOT!
4. Replace the lens and screw.