Télécharger Imprimer la page

Broan Elite RME50000 Serie Mode D'emploi page 7

Publicité

Les langues disponibles

Les langues disponibles

2. Attach an adequate length of 6" round steel
ducting to the range hood duct connector.
Fig.6
3. Duct tape all joints to make them secure
and air tight.
4. Carefully place the lower decorative flue
into the recessed area of the range hood
top. Fig. 7
5. Carefully slide the upper decorative flue
down inside the lower flue. Fig. 7
INSTALL THE HOOD
Note: at least two people will be required to
mount the hood.
1. Raise the hood into its
mounting position.
2. Plug the power cord into
the electric wall recep-
tacle. Tuck excess cord
behind the flue.
3. Align the rectangular
opening on the back of the
hood with the wall-
mounting bracket. Gently
lower the hood until it
securely engages the
bracket. Fig.8
4. Level the hood.
Height adjustment screws provide
vertical adjustment.
Secure the hood with mounting screws
(4.8x38mm). Use drywall anchors,
provided, if wall studs or framing are not
available.
Secure with (2) mounting screws
(4.8x38mm). Use drywall anchors provided
if wall studs or framing are not available.
Fig.8
5. Raise the upper flue until its holes align
with holes in the flue mounting bracket
(located on ceiling). Fig.9
6. Secure the flue with (2) mounting screws
(3.9x9.5mm). Fig.9
UPPER
FLUE
LOWER
FLUE
HEIGHT
ADJUSTMENT
SCREWS
(3.9x9.5mm)
MOUNTING
SCREWS
(4.8x38mm)
7
UPPER
VENTS
EXPOSED
CONCEALED
WALL FRAMING
MOUNTING
BRACKET
MOUNTING
SCREWS
(4.8x38mm)
RECTANGULAR
CUTOUT
FASTEN FLUE TO
UPPER BRACKET
WITH SCREWS (3.9x9.5mm)
FLUE
UPPER
FLUE
VENTS
BEHIND
LOWER
FLUE
fig.7
fig.8
fig.9

Publicité

loading