14.1 Safety notices
Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.
14.2 Fault indications
In the event of a fault, an error code will appear in the display; it describes the
cause of the fault.
Error code
Description
E01
Excessive temperature within cooking chamber
The overheating cut-out terminated the current program at a cooking
chamber temperature of 250°C.
Press the Stop button to acknowledge this fault.
The device can be re-activated after the cool down phase.
E03
Sensor fault
The device has detected an error on a sensor and has terminated the
current programme.
Press the Stop button to acknowledge this fault.
Please note
► If error messages continue to appear after an extended waiting period and restarting the
device, then the device will need to be sent to Customer Service to be inspected.
14.3 Causes and rectification of faults
The following table assists in localizing and rectifying minor faults.
Error
The selected program
will not start.
The turntable turns
jerkily.
caso MCG20 Chef
Possible cause
Device door is not closed
Power plug is not plugged in
Fuse is not activated
Dirt between the turntable and
the base of cooking camber
Dirt on rolling ring
Cooking vessel too large
Action
► Close device door
► Plug in mains plug!
► Activate fuse
► Remove dirt
► Use different cooking
vessel
69