Télécharger Imprimer la page

Balluff BTL7-V50D-M Serie Notice D'utilisation page 34

Masquer les pouces Voir aussi pour BTL7-V50D-M Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
BTL7-V50D-M _ _ _ _ -A/B/Y/Z(8)-C003
Transducer — Rod Style
4
Installation and connection (continued)
Magnets
(e.g. BTL-P-1028-15R)
Supporting rod made of non-magnetizable material
Fig. 4-8:
Example 2, transducer installed with supporting rod
4.4
Electrical connection
The transducer is connected via a connector.
The pin assignments for the respective version can be
found in Tab. 4-2 and Tab. 4-3.
Note the information on shielding and cable
routing.
4.4.1
Connector BTL7-...-C003
1
4
Bus OUT/
Port2
3
(socket)
Fig. 4-9:
Pin assignment of connector (view from above on
transducer)
Power
Pin
Cable color
1
BN brown
2
WH white
3
BU blue
4
BK black
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Reference potential for supply voltage and EMC-GND.
2)
Tab. 4-2:
Pin assignment of ...-C003 connector, supply
12
english
Power
3
1
(pin)
4
2
3
2
2
4
Bus IN/
Port1
1
(socket)
Signal
10...30 V DC
Not used
1)
0 V GND
2)
Not used
1)
BUS IN/OUT (data)
Pin
Cable color
1
YE yellow
2
WH white
3
OG orange
4
BU blue
Tab. 4-3:
Pin assignment of ...-C003 connector, BUS IN/OUT
4.5
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect transducer and controller using a shielded
cable.
Shielding: Braided copper shield with minimum 85%
coverage.
Shield is internally connected to connector housing.
Magnetic fields
The transducer system is a magnetostrictive system.
Ensure that there is sufficient distance between the
transducer and between the transducer/holding cylinder
and strong, external magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Cable length
The maximum cable length when using CAT5e cables is
100 m
.
3)
Prerequisite: Construction, shielding and routing preclude the effect of any
3)
external noise fields.
Signal
TX+
RX+
TX−
RX−

Publicité

loading