Télécharger Imprimer la page

RIB ACG6154 Mode D'emploi page 32

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G
B
signalling while the red LED of the RED transmitter flashes 3 times to confirm the correct
set up.
VERIFY THE CORRECT OPERATION OF THE PEDESTRIAN DOOR SECURITY
Open the pedestrian door, opening NC contact connected to the RED transmitter. Verify that
on the MASTER NO TOUCH 868 the LEDs DL3 and DL4 turn off and that any door opening
command is not performed.
ANTENNA
To communicate with the safety devices, MASTER NO TOUCH 868 is equipped with a
piece of electrical wire which serves as an antenna connected to J3 terminal. If it becomes
necessary to improve the radio signal (for example when MASTER NO TOUCH 868 is
installed in a metal container), connect the 868.3 MHz antenna (code ACG5451) to the J3
terminal, respecting the connection of the central and ground wire, and position it in a way
that is 'in sight' by all safety devices.
To make the system work properly, it is necessary that between the MASTER NO
TOUCH 868 and the safety devices, there are not any obstacles such as concrete
walls, iron surfaces etc. which could interfere with radio signals.
WARNING STATUS (alert to change batteries)
The warning status (WARNING) alerts the user that it is imminently necessary to change
batteries.
When the batteries of NO TOUCH 868 are low and reach 3,1V, NO TOUCH 868 receiver
sends a signal via radio to MASTER NO TOUCH 868 that the batteries are nearly dead.
MASTER NO TOUCH 868 will activate the BUZZER with a tone every 3 seconds for a duration
of 1 minutes every time you give a command to the automation.
The bi-colour LED DL1 on MASTER NO TOUCH 868 will turn on fixed red.
During these status signals the system is still operating, but it is advisable to change the
batteries as soon as possible in order to avoid the door to stop operating, which happens
when the battery reaches 2,8 V.
ALARM STATUS (battery completely dead or failure)
The alarm status is active when the batteries are completely dead (2,8V) or in the event
of failure.
On the MASTER NO TOUCH 868the LEDs DL3 and DL4 turn off and automation remains
stationary while the bi-colour LED DL1 flashes alternate red-green (for the entire duration)
and the BUZZER emits an alternate tone for 1 minute.
To stop the alarm you must replace the batteries or repair the failure.
PROCEDURE FOR CANCELLATION OF SAFETY DEVICE/S
To cancel safety device/s stored on MASTER NO TOUCH 868 proceed in the following way:
- Press and keep pressed the PROG. RX pushbutton for 10 seconds.
- At the end of the 10 seconds, the bi-colour LED DL1 flashes 6 times alternatively from red
to green, signalling the cancellation, while the LEDs DL3 and DL4, if lighted, will turn off.
TECHNICAL CHARACTERISTICS OF MASTER NO TOUCH 868 code
ACG6154
- SUPPLY
- VOLTAGE APPLICABLE TO TERMINAL J2
- VOLTAGE APPLICABLE TO TERMINAL J1
- CONSUMPTION AT REST
- MAXIMUM CONSUMPTION
- WORKING TEMPERATURE
- DIMENSIONS
- WEIGHT
TECHNICAL DATA OF RADIO FREQUENCY
- FREQUENCY
- SENSITIVITY
- OUTPUT POWER
- TYPE OF MODULATION
- RANGE
TECHNICAL CHARACTERISTICS OF NO TOUCH 868 PHOTOCELL code
ACG8048
NO TOUCH 868 RECEIVER
- SUPPLY
- CONSUMPTION AT REST
- MAXIMUM CONSUMPTION
- TYPE OF MODULATION
- BATTERY LIFE
- WORKING TEMPERATURE
- MAXIMUM TIME OF REACTION (TIME OF ACTIVATION OF THE RECEIVER WHEN
ENGAGED)
- TIME FROM RECOVERY TO RELEASE 90 ms
- DEGREE OF PROTECTION
- DIMENSIONS
- WEIGHT
TECHNICAL DATA OF RADIO FREQUENCY
- FREQUENCY
- SENSITIVITY
- OUTPUT POWER
- RANGE
NO TOUCH 868 TRANSMITTER
- POWER SUPPLY
- CONSUMPTION
- TYPE OF MODULATION
- BATTERY LIFE
- BATTERY LIFE WITH JUMPER JP4 IN "L" POSITION
- BATTERY LIFE WITH JUMPER JP4 IN "H" POSITION
- WORKING TEMPERATURE
- DEGREE OF PROTECTION
- DIMENSIONS
- WEIGHT
TECHNICAL DATA OF INFRARED SIGNAL
- WAVELENGTH
- RANGE
12/24V
110-240V 50/60Hz
10-30V
30 mA
100 mA
-20°C ÷ +60°C
125x55x28 mm
0,090 kg
868.3 MHz
-108 dBm
<25 mW
FSK
20 m in open space
32
1 x LITHIUM AA 3.6V (>2.5 Ah) batteries
5 µA
25 mA
FSK
about 3 years (with 10 daily cycles)
-20°C ÷ +60°C
90 ms
IP54
Total height with bracket = 190 mm;
width = 34.60 mm;
depth = 32 mm
0,210 kg
868,3 MHz
-108 dBm
<25 mW
20 m in free space without antenna
1 x LITHIO AA 3.6V (>2.5 Ah) batteries)
3 µA
FSK
about 3 years
Range of the infrared signal 5 m:
3,1 years
Range of the infrared signal 10 m:
1,2 years
-20°C ÷ +60°C
IP54
Total height with bracket = 190 mm;
Width = 35 mm;
Depth= 51,91 mm
0,210 kg with battery
890 nm
10 m with jumper JP4 in "H" position on TX
(default set to 5 m with jumper JP4 in "L"
position)
4
3
2
1
0
5
10
Daily cycles
batteries life
20
30