NO TOUCH 868 complies with the standard EN13849-2:2013 and, in junction with a
RIB electric panel equipped with AUTOTEST, is a Class 2 protection device.
The system constantly monitors the presence of the various security devices and battery
status, satisfying the need for fully active security on all types of doors with vertical
movement.
NO TOUCH 868 is a patented device developed to guarantee safety in automations such as
shutters and sectional doors.
The NO TOUCH 868 photocells prevent contact with any obstructions, thanks to their infrared
ray which is 13cm away from the door.
NO TOUCH 868 does not require cable reel systems, because it operates with batteries
and via radio.
The particular system of "balance" allows the control of each movement condition, even
when vibrations are present.
The system is composed of three elements:
1 - 868 MHz radio transceiver, MASTER NO TOUCH 868 (cod. ACG6154) connected to
the door electric control panel.
2 - Aerial 868MHz
3 - Infrared transmitter.
4 - Infrared receiver with 868 MHz radio transceiver which constantly communicates
with the MASTER NO TOUCH 868.
2
3
59
35
Measurements in mm
1
4
35
35
51,91
25
MASTER NO TOUCH 868 can handle two security devices:
- PHOTOCELL NO TOUCH 868 (code ACG8048). THE NO TOUCH 868 PHOTOCELLS ARE
ON ONLY WHEN THE DOOR IS IN OPERATION. Thanks to the SLEEP MODE function,
when the door is closed, the photocells are turned off, saving the battery life.
- Additional security: RED TRANSMITTER (code ACG6202) connected to NC (not
supplied) to be applied to the pedestrian door on the main door. It will only work if you
have already programmed the NO TOUCH 868 photocell.
THE RED TRANSMITTER IS ALWAYS ACTIVE AND WHEN THE PEDESTRIAN DOOR
IS OPENED (and thus the NC contact to which it is linked is open) LOCKS THE
OPERATION OF THE MAIN DOOR.
REFERENCE TO STANDARDS FOR AUTOMATIC VERTICAL DOORS
Once machine installation is complete it must be ascertained that it complies with standard
EN13241-1.
RIB MAY NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED BY IMPROPER, WRONG
OR UNREASONABLE USE.
Usage restrictions: The NO TOUCH 868 photocells cannot be used on devices excluded by
the application of the EN12978, such as:
- protection devices for the installation on doors used for a different purpose to those ones
used for pedestrian or veheicle access, covered by the norm which principal intent is that
of allowing a safe access to industrial, commercial, public and commercial sites. Some
examples of excluded accesses can be: sluice gates, dams, lift doors, vehicles' doors, doors
used mainly to restrain animals, theatre curtains, railways barriers, barriers used only for
vehicles.
- Devices used only fo the standard control and for the stopping, including the emergency
stopping, of motorized doors.
- Safety systems and safety devices used on machineries different from doors.
ATTENTION: Any possible modification of the device, or of the configuration of the same cannot
be carried out without the clear authorization by the manufacturer or, by the local authorized
dealer.
The installer of the safety device must make sure that the end user know the
following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any obtsacle.
- About the procedures for cleaning so to avoid the dangerous building up of material.
- The possible details for a restart of the system after an emergency or accidental stop caused
by the control system.
Any modification of the project or, of the configuration of the device, without discussing it first
with the manufacturer or with the local autorized dealer can cause dangerous situations.
G