Télécharger Imprimer la page

RIB ACG6154 Mode D'emploi page 26

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G
B
MASTER NO TOUCH 868 (15/09/2014)
LAYOUT
J3
JP2
J1 =>
COM
CONTACT N.C.
POWER - 12/24 V
POWER + 12/24 V
AUTOTEST
ALARM N.C.
J2 =>
120/230 Vac
TERMINALS TO BE CONNECTED TO THE 120/230V 50/60Hz BLINKER OUTPUT OF THE ELECTRONIC CONTROL PANEL
J3 =>
TERMINAL FOR CONNECTING THE 868,3 MHz ANTENNA
J4 =>
12/24 V
TERMINALS TO BE CONNECTED TO THE 12/24V
PAY CLOSE ATTENTION TO THE POLARITY INDICATED ON THE PRINTED CIRCUIT
JP1 =>
AUTOTEST SUPPLY SELECTION
JP1-
Jumper autotest selection mode with negative supply
JP1+/~ Jumper autotest selection mode with positive supply or AC (for use with RIB panel model J)
JP2 =>
A provision for future implementations
S1 =>
PROG. RX Programming pushbutton
BUZZER =>
Signals, through different sounds, possible adjustments to be made during installation and events of warning or alarm
LED
DL1 (bi-colour)
off
=> normal operation
green
=> photocell engaged
red/green => alarm
DL2 (yellow)
- presence of supply voltage 12-24V
DL3 (red)
- N.C. CONTACT
DL4 (red)
- N.C. ALARM
ATTENTION: THE MASTER NO TOUCH 868 CANNOT be installed more than 3 metres away from the control panel of the door operator.
DL2
S1
DL1
DL3
=> common in NC contact
=> usually closed contact to be connected to the Strip or Photocell in the electric control panel
=> negative supply 12/24V
=> positive supply 12/24V
=> supply for AUTOTEST (see also JP1 for the selection)
=> usually closed contact to be connected to the STOP input on the electric control panel
BLINKER OUTPUT OF THE ELECTRONIC CONTROL PANEL
BUZZER
J1
DL4
J2
26
-
+
J4
JP1

Publicité