Programming for partial opening
With the door is completely closed, set DIP switch 2 to ON (the signalling led fl ashes).
Press and keep the OPEN button pressed until the door reaches the desired point of opening...
...then press the ENC/RADIO button (if the signalling LED stays on the programming procedure is successfully complete).
Set DIP switch 2 back to OFF
Programming for decelerated opening when door is open (50% of the opening arc max.)
Note: before programming, deactivate the automatic closing by adjusting the A.C.T. Trimmer to its minimum setting.
With the gate completely open, press and keep pressed the ENC/RADIO button (the signalling programming led fl ashes quickly).
Set DIP switch 1 to ON (the signalling LED turns off).
Release the ENC/RADIO button (the signalling LED fl ashes slowly).
Press the OP/CL button until the gate reaches the fi nal point of deceleration you require; then press the ENC/RADIO button until the
signalling LED staus on ( the programming procedure is completed succesfully).
Set DIP switch 1 back to OFF.
Programming for closing deceleration (600 mm from the closing stop minimum, or 50% of the opening/closing arc)
With the door completely closed, press and keep pressed the ENC/RADIO button (the signalling programming LED fl ashes quickly).
Set DIP switch 2 to ON (the signalling LED turns off).
Release the ENC/RADIO button (the signalling LED fl ashes quickly).
Press the OPEN button until the door reaches the point of beginning deceleration you require; then press the ENC/RADIO button until the
signalling LED stays on (the programming procedure is successfully completed).
Set DIP switch 2 back to OFF.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

Publicité