7 TROUBLE-SHOOTING

7.1 ALARMS MANAGEMENT
The "OMEGA" electronic card is a powerful control logic unit which signals possible
machine troubles by means of alphanumeric messages visualised on the display; the
technician shall understand them to quickly find the reason of this trouble.
MESSAGE
EME
EMERGENCY
TER
When a motor thermal cutout is triggered, it is followed by
MOTOR
THERMAL
CUTOUT ALARM
When the machine is started up, the microprocessor checks
EPO
the data stored in the EPROM memory: if this data are not
STORED DATA
ALARM
EPI
acknowledged, EPI will appear on the display, followed by
MEMORY ALARM
LI
If, during normal functioning, the voltage is too low, LI will
POWER SUPPLY
ALARM
OUT
If, during normal functioning, the output control module is
faulty or if it is not acknowledged, OUT will appear on the
USCITE MODULE
ALARM
TA
transformer occurs, TA will appear on the display, followed
TA ALARM
UTA
TA MICRO-
occurs, UTA will appear on the display, followed by the
PROCESSOR
ALARM
17 - ENGLISH
DESCRIPTION
The door is open or the safety grid on the hopper is not
completely lowered.
An intermittent beep is released.
the blinking of the led TER and by the release of an
intermittent beep.
correct EPO will appear on the display, followed by the
release of an intermittent beep.
If, during normal functioning, the memory is not
the release of an intermittent beep.
appear on the display, followed by the release of an
intermittent beep.
display, followed by the release of an intermittent beep.
If, during normal functioning, an anomaly of the current
by the release of an intermittent beep.
If, during normal functioning, an anomaly of the
microprocessor controlling the consistency calibration
release of an intermittent beep.
REMEDIES
Make sure that the door
is closed and the safety
grid on the hopper is
lowered.
After checking the
machine, press STOP to
restore correct
functioning.
Send for a technician.
Send for a technician.
Check mains voltage
and machine power
supply.
Send for a technician.
Send for a technician.
Send for a technician.