THE BOILER REMAINS OUT OF POWER:
6.4.
Make sure the boiler is connected and the plug is leading power.
6.5.
Make sure the cable is not damage or cut.
While the boiler is disconnected, dismantle the right door of the boiler and check if any lead of the C.P.U. is
slack.
6.6.
Check the C.P.U. pilot. If it is OFF, check also the fuse on the C.P.U.
PELLETS DO NOT FALL AND THE BOILER DOES NOT TURN ON:
6.7.
Check if there are pellets in the hopper.
6.8.
Make sure the glass door is closed.
6.9.
Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10. Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11. With the boiler unplugged, check that the safety thermostat is located at the back, to the right side of the
boiler. To activate it, you must unscrew the cap and press the button if necessary. If the thermostat is activated
you will hear a "click". If the safety thermostat had been activated before, consult your dealer.
6.12. If the reducer motor receives current and rotate slower than usually, it may have something blocked such as a
screw, a piece of wood, etc. To solve this problem, you must empty the hopper and, even if necessary, to
remove the auger screen.
WHAT DO TO IF...