Télécharger Imprimer la page

Kohler K-3608 Guide D'installation Et D'entretien page 9

Publicité

Troubleshooting Guide
Symptoms
Recommended Action
1.
Poor flush.
A.
Adjust the tank water level to match the waterline.
B.
Fully open the water supply shut-off valve.
C.
Clear obstructions from the trapway, jet, or bowl rim holes.
D.
Clear obstructions from the waste line.
2.
No flush.
A.
Reconnect the flapper chain to the trip lever or flush valve.
B.
Adjust the flapper chain assembly to remove excessive slack.
3.
The fill valve
A.
Adjust the flapper chain for proper slack so the flapper closes.
turns on/off
by itself
without the
toilet being
flushed, or it
runs, allowing
water to enter
the tank.
B.
Clean or replace the flapper if it is worn, dirty, or misaligned
with the opening.
C.
Clean the area around the opening to allow the flapper to seal.
D.
Adjust the tank water level if it is too high.
E.
Replace the fill valve if the valve float sinks.
Tank takes
Fully open the water supply shut-off valve.
4.
A.
excessive time
to fill.
B.
Check the flexible supply line (if applicable) for a kink.
Remove the kink.
C.
Clean the valve inlet, valve head, or supply line. Flush the
lines.
5.
There is
A.
Partially close the water supply shut-off valve if the water
excessive noise
pressure to the toilet is too high. Check the toilet performance
when the tank
following any such adjustment.
is filling.
B.
Remove dirt or obstructions from the valve head. Flush the
lines.
Guide de dépannage
Symptômes
Action recommandée
1.
Faible chasse.
A.
Régler le niveau d'eau du réservoir au niveau du repère.
B.
Ouvrir complètement la valve d'arrêt d'alimentation.
C.
Dégager toutes obstructions du siphon, du jet ou des trous du
rebord de la cuvette.
D.
Dégager toute obstruction de la ligne d'évacuation.
2.
Pas de chasse.
A.
Raccorder la chaîne du clapet au levier de déclenchement ou à
la valve de chasse.
B.
Régler l'assemblage de la chaîne du clapet pour éliminer tout
jeu excessif.
Kohler Co.
9
1092036-2-A

Publicité

loading

Ce manuel est également adapté pour:

K-3608-0K-3608-96