Carrying Out A Firmware Update - Weller WX 2 Mode D'emploi

Masquer les pouces Voir aussi pour WX 2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
18-20
Fig. 36
Fig. 37
Fig. 38: front WFE
connection
7.3

Carrying out a firmware update

1. Switch off the WX 2 Soldering Station.
2. Insert the memory stick into the USB port.
3. Switch on the WX 2 Soldering Station.
The firmware update is performed automatically (see Fig. 36).
If you have a more already installed more recent firmware on your
station, this will not be changed.
Note
The station must not be switched off while the firmware update is
running.
7.4
Connecting auxiliary devices
Please observe the overview diagrams (Fig. 1 and Fig. 2).
Auxiliary devices can be connected either to the port on the front
panel (11) and/or to the port on the back (15) of the WX 2 Soldering
Station.
The WX 2 Soldering Station detects automatically which auxiliary
device is connected. The WX 2 Soldering Station shows the symbol
or name of the connected auxiliary device (31/25) on the left (front
port (11), see Fig. 38) or right (rear port).
7.5
Setting the parameters of auxiliary devices
Please observe the overview diagrams (Fig. 1 and Fig. 2).
1. Select the auxiliary device using the auxiliary device key
(front/back) (6, 13).
The variable parameters (e.g. speed) are displayed.
2. Set the required value using the turn-and-click wheel (7).
3. Confirm the value with the Enter key (8)
or
press key 6 to exit.
WX 2

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières