Télécharger Imprimer la page

GENERGY LIMITED 2000I INVERTER Instructions D'utilisation page 62

Publicité

Les langues disponibles

Les langues disponibles

8.1 Oil change
Keep the engine running during 5 or 10 minutes, so that the oil can reach some
temperature and decrease its viscosity (more liquid). In this way, it will be easier to
extract it completely.
1. Remove the oil refill cap (A) turning counterclockwise. Keep the cap in a visible
place.
2. Place a suitable container to collect the used oil, near of the generator.
3. Tilting the generator (B), let all oil pours into the container. Keep the generator
tilted during several minutes to ensure that the most part of the oil was expelled.
4. Once all engine oil has been extracted, clean up any spillages.
5. Refill with oil, according to the recommendations of chapter: 4.2 Oil filling and
checking.
IMPORTANT: To safeguard the environmental regulations, the used oil must be
placed in a sealed container and delivered to a service station for recycling. Do not
put it in the trash or spill it on the ground.
59

Publicité

loading

Ce manuel est également adapté pour:

Limited 2000i e-start inverter