7.4 DC Output 12V
The generator has a direct current (DC) output of 12V with an intensity of 8.3Ah
(A). The unique purpose of this output is to charge the battery in case of
emergency and when there is not a charger 230V AC available.
In case of a short circuit, the circuit breaker (B) cuts off the direct current (DC)
output for protection. To restore the current output, press the circuit breaker.
The approximated charge time of the battery will be:
 20Ah:
2.5hours
 50Ah:
6.0hours
 100Ah: 12hours