2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Schematic diagram of parameters related to torque, angle, and speed.
Ignore load and don't shut-off
Snug Torque Detection Delay
Switch ON
Angle Before Snug
No Load Speed (1300 to 1900 rpm)
Variable Speed Control (ON, OFF)
Soft Start (ON
the tool lowest rpm: about 210 rpm
EN
Snug Torque
Angle
Before Snug
Lower Limit
the tool lowest rpm, OFF)
Torque Upper Limit
Shut-Off Torque
Torque Lower Limit
Angle After Snug
Angle
Before Snug
Upper Limit
- 68 -
Torque
curve
Angle
Angle
After Snug
After Snug
Lower Limit
Upper Limit