Télécharger Imprimer la page

Danfoss CF-MC Instruction page 8

Masquer les pouces Voir aussi pour CF-MC:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Instruction CF-MC Master Controller
5.7 External Antenna (CF-EA)
Note: The External Antenna is installed as diverter when there is NO transmis-
sion possible through a large building, heavy construction or metal barrier, e.g.
if the Master Controller is located in a metal cabinet/box
• Remove the plastic cover from the antenna connection on the Master
Controller. ( g. 19)
• Connect the External Antenna. ( g. 20)
• Place the External Antenna on the other side of the transmission barrier
away from the Master Controller.
5.8 More (2-3) Master Controllers
Notes: Master Controller #1 should be the one connected to the local supplying
pump.
Up to 3 Master Controllers can be connected in one system.
If there are 2 or 3 Master Controllers, connect them to a 230V power sup-
ply within a distance from Master Controller #1 that allows simultaneous
handling of all the Master Controllers
Activate Install mode on Master Controller #1( g. 21)
• Use the menu selection button
ashes
• Activate Install mode by pressing OK . Install LED
Initiate installation on Master Controller #2 or #3( g. 22)
• Activate installation to Master Controller #1 by pressing OK
• Install LED
and
and goes OFF when installation is complete
• Relocate Master Controller #2 and/or #3 if necessary. Link test will be
initiated automatically on reconnection to 230V power supply
• If Master Controller #2 and/or #3 has it's own pump, the relays for pump
and boiler must be con gured accordingly (see 6.4)
Note: Later removal of Master Controller #2 or #3 from Master Controller #1 can
only be done by resetting Master Controller #1 (see 7.2)
5.9 Other System Components
Note: The Installation procedure of other system components to the Master
Controller (Room Thermostats, Remote Controller, and Repeater Unit ; see 2.) is
described in the enclosed instructions for these system components. Please see
these instructions for speci c installation procedures
VI.UH.K2.80
to select the Install mode. Install LED
ickers during communication
Produced by Danfoss Floor Heating Hydronics 01.2006
goes ON
7

Publicité

loading

Ce manuel est également adapté pour:

088u0200088u0205