I NSTAL L AT IO N
Installation
WARNING
Wall framing must be able to support the weight of the
hood and internal blower, if applicable.
WARNING
Failure to install the screws or fixing device in accor-
dance with these instructions may result in electrical
hazards.
Refer to the illustration below for typical wall framing.
1
Additional framing or blocking is required in the
mounting strip location.
457
mm
BLOCKING
MOUNTING
TO BOTTOM
STRIP
OF HOOD
C L
Wall framing (typical)
Remove the wood mounting strip from the back of the
2
hood by extracting the screws from inside the hood.
Remove the electrical box from the inside the hood.
3
Remove the transition from inside the hood by removing
4
the hold-down brackets. Remove the shipping material
from the damper. Refer to the illustration below.
Mount the transition and hold-down brackets to the top
5
of the hood using the existing screws. Refer to the illus-
tration below.
For internal blowers, install the blower prior to mounting
6
the hood. Refer to the instructions provided with the
blower.
HOLD-DOWN
TRANSITION
BRACKET
TRANSITION
Transition position (shipping)
Transition mounting
Position the mounting brackets on the mounting strip
7
as shown in the illustration and chart below. Secure the
brackets to the mounting strip with the provided screws
and washers.
M O U N T I N G B R A CK ET L O C AT I O N
762 mm Hood
914 mm Hood
1067 mm Hood
1219 mm Hood
1524 mm Hood
1232 mm
A
13 mm
MOUNTING
MOUNTING
STRIP
BRACKET
C L
Mounting bracket location
Position the mounting strip on the wall and secure it to
8
the wall framing with the wood screws provided. Refer to
the illustration below.
Lift the hood into position and insert electrical supply
9
cable into the electrical knockout and secure with a UL
A
or C/UL approved connector (not provided).
597 mm
Secure the hood to the mounting strip and wall structure
10
622 mm
with the provided screws and washers.
775 mm
Connect the ducting to the transition and secure with
11
927 mm
duct sealing tape.
MOUNTING STRIP
384
mm
Hood installation
wolfappliance.com | 5