SP EC I FI C AT IO N S
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustration
below. A separate circuit, servicing only this appliance is
required.
E L E C TR I CA L R E Q U I R E ME N T S
Electrical Supply
220-240 V AC, 50/60 Hz
Service
15 amp dedicated circuit
E
127
mm
762 mm
914 mm
TO
BOTTOM EDGE TO COUNTERTOP
Electrical location
RATING PLATE
Rating plate location
4 | English
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
152
mm
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
Discharge
Pro Wall Hoods have a vertical discharge. Refer to the
illustration below.
143 mm
54 mm
TO CENTER
OF TRANSITION
Vertical discharge
Hood Preparation
Remove the filters, spacers, and grease cup(s) prior to
installation.
To remove the filters, press upward, then rotate the bottom
downward. To remove the spacers, slide the spacer toward
the center of the hood slightly. Press upward and rotate the
bottom downward. To remove the grease cup(s), lift verti-
cally to remove from the rear flange. Refer to the illustrations
below.
SPACER
Filters
Spacer
FLANGE
GREASE
CUP
Grease cup