Elba 1104288 - B1 Mode D'emploi page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTION OF THE POWER SUPPLY CABLE
Unhook the terminal board cover by inserting a screwdriver into the two hooks A (fig.
8.1).
Unscrew the screw D and open completely the cable clamp E (figs. 8.2 - 8.3 - 8.4).
Position the U bolts F onto terminal board G (figs. 8.2 - 8.3 - 8.4) according to the
diagrams in fig. 8.5.
Connect the phase, neutral and earth wires to terminal board G according to the dia-
grams in fig. 8.5.
Strain the feeder cable and block it with cable clamp E (by screwing screw D).
Close the terminal block cover (check the two hooks A are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
Fig. 8.1
FEEDER CABLE SECTION
"TYPE H05RR-F or H05VV-F"
220-240 V ac
380-415 V 3N ac
380-415 V 2N ac
(**) Connection with wall box connection.
A
Diversity factor applied.
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.
3 x 6 mm
(**)
2
5 x 2,5 mm
(**)
2
4 x 6 mm
(**)
2
45

Publicité

Table des Matières
loading

Table des Matières