Centre the running belt (fig. F-5)
Centre the running belt is needed when your running belt is not
tracking in the centre of your running surface. This is noticed easily
when the gap between side landing and running belt is significantly
bigger on one side compared to the other side.
This can be caused by a few reasons, such as:
REASON 1
You do a workout using one leg more powerful in push off during
your workout. This causes the belt being pushed aside, but will
correct automatically when let the running belt run unloaded for a few
minutes.
REASON 2
Your treadmill is not levelled horizontally, where gravity pulls the
running belt slowly to the lowest end of the treadmill. This must be
corrected by levelling the treadmill correctly. as this cannot be solved
by any other adjustment.
REASON 3
The running belt is not centred correctly between the front and rear
roller drum. This needs be corrected by adjusting the running belt
tracking as described below.
To adjust the running belt's tracking use the Allen key being provided
with your treadmill.
- Set your treadmill at a speed of ± 5 km/h, not running on it.
- When the running belt is tracking to the right side.
Turn the left-hand rear roller adjustment bold, located on the rear
end in a socket in the rear roller cover, counter clockwise for 1/4
turn.
- When the running belt is tracking to the left side.
Turn the right-hand rear roller adjustment bold, located on the rear
end in a socket in the rear roller cover, counter clockwise for 1/4
turn.
- Await ±2 minutes to give the running belt the time to respond to
the adjustment before repeating the adjustment steps if needed to
get to the desired result.
‼ NOTE
• Remember, a small adjustment can make a big difference, so
make the adjustments with small steps at the time.
Click to see our supportive YouTube video
https://youtu.be/qx5AvTv00J4
The belt may require periodic tracking adjustment depending on use
and walking/running characteristics. Some users will affect tracking
differently. Expect to make adjustments as required to centre the
tread-belt. Adjustments will become less of a maintenance concern
as the belt is used. Proper belt tracking is an owner responsibility
common with all treadmills.
‼ NOTE
• Damage to the running belt because of incorrect running-belt
adjustments is not covered by the products warranty.
Troubleshooting
Despite continuous quality control, defects and malfunctions caused
by individual components may occur in the equipment. In most cases
it's unnecessary to take the whole device in for repair, as it's usually
sufficient to replace the defective part.
If the equipment does not function properly during use, contact your
Tunturi dealer immediately. Always give the model and serial number
of your equipment. Please state also the nature of the problem,
conditions of use and purchase date.
If you require spare parts, always give the model, serial number of
your equipment and the spare part number for the part you need.
The spare part list is at the back of this manual. Use only spare parts
mentioned in the spare part list.
Error codes
If the display shows an error code
(marked with "E" + number), restart the equipment and check
whether the display still shows the error code. If the display still shows
the error code, immediately contact the dealer.
Oil
OIL is not an error code, see "Lubrication"
E5
Means a power fault�
When rebooting the T90 treadmill it is important to await at least
30 seconds. The treadmill must be 30 seconds in off mode before
starting up again. When resart too fast, E5 will appear always.
This because the AC motor motor controller needs longer time to
fully shut down, and keeps processing even after console is shut in off
mode already for at least 15 seconds.
Solve the problem by shut down the treadmill by turning the power
switch in off mode. Await 30 seconds and turn power switch in ON
mode again. E5 error code should not appear anymore.
If error code keeps coming still, contact your dealer for service.
E7
Console will show E7 code when safety key is not in (correct) position
during start up.
E7 is not an error code, see "Safety key"
Metric/ Imperial setting
When displayed speed is not matching your expectation the machine
might be set in incorrect setting.
Metric:
Min./ Max. speed/:
0.8 Km/h/ 24.0 km/h.
Imperial:
Min./ Max. speed/:
0.5 Mls/h/ 15.0 Mls/h.
Switch units by:
In mode "ON":
- Press and hold "Prog" & "Speed -" button for 3 seconds.
Console shows S-01 mode:
- 0.6 When switched to Imperial mode.
- 1.0 When switched to Metric mode.
- Press "Mode" button to switch setting.
Press "Start/ Pause" button to confirm setting and go back to user
mode again.
https://youtu.be/K Oxl5obz-RQ
2 5
English