Table 2
DROP 4.5
DROP 6
DROP 9
NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 50 cm from the floor.
Open the cover of the heater's electrical box.
L1 L2 L3
N
3/N ~400V
Attach the power cable on the terminal block according to the
circuit diagram.
Close the cover.
Fix the cable on the output with a cable strap.
Install the heater on the wall frame.
Fittingthestones
Upon stacking the stones, one should monitor that the heating
elements are not bent and that there is a sufficient air circulation
around the heater elements.
The stones must be washed clean before laying.
Stack the stones sparsely between the heating elements. When
the stones have been stacked too close to each other, the heating
elements may overheat (= shorter useful life) and slow the heating of
the sauna.
6
Output
Elements
kW
4,5
6
8,5
1,5 / 2
Circuit Breaker
kW
1,5
3 × 10
2
3 × 10
3 × 16
Power cable
A
mm
5 × 1,5
5 × 1,5
5 × 2,5
2