IO-Link Data Dictionary
21.10.01.00065/03
IO-Link Implementation
Vendor ID
Device ID
Device ID (IMP)
SIO-Mode
Baudrate
Minimum cycle time
Processdata input
Processdata output
Process Data
Process Data In
Signal H2 (part present)
Signal H1 (automatic air saving function)
-
CM-Autoset acknowledged
PD In Byte 0
EPC-Select acknowledged
Device status - green
Device status - yellow
Device status - red
PD In Byte 1
EPC value 1
PD In Byte 2
EPC value 2, high-byte
PD In Byte 3
EPC value 2, low-byte
Process Data Out
Vacuum
Blow-off
Vacuum with forced control
CM Autoset
PD Out Byte 0
EPC-Select
Profile-Set
PD Out Byte 1
Input pressure
ISDU Parameters
(all ISDUs use subindex 0 only)
ISDU Index
Display
Parameter
Appearance
dec
hex
Identification
16
0x0010
Vendor name
Vendor text
17
0x0011
18
0x0012
Product name
Product text
20
0x0014
250
0x00FA Art
Article number
Article revision
251
0x00FB
22
0x0016
Hardware revision
23
0x0017 SoC
Firmware revision
21
0x0015 Snr
Serial number
Application specific tag
24
0x0018
Parameter
Access Locks
12
0x000C
Device access locks
77
0x004D Pin
PIN code
J. Schmalz GmbH
Name
Bits
0
1
2
3
4
5
6
7
7...0
7...0
7...0
Name
Bits
0
1
2
3
5..4
7..6
7...0
Data width
Value range
15 bytes
15 bytes
8 bytes
30 bytes
14 bytes
2 bytes
2 bytes
4 bytes
9 bytes
0...32 bytes
2 bytes
0 - 7
2 bytes
0 - 999
J. Schmalz GmbH
Johannes-Schmalz-Str. 1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
info@schmalz.de
IO-Link Version 1.1
234 (0x00EA)
234 (0x00EA)
100243 (0x018793)
100242 (0x018792)
100247 (0x018797)
-
Yes
Yes
38.4 kBd (COM2)
38.4 kBd (COM2)
3.5 ms
3.0 ms
4 byte
1 byte
2 byte
1 byte
Access
Availability
ro
IO-Link V1.1, V1.0
Vacuum is over H2 & not yet under H2-h2
ro
IO-Link V1.1, V1.0
Vacuum is over H1 & not yet under H1-h1
ro
-
unused
ro
IO-Link V1.1, V1.0
Acknowledge that the Autoset function has been completed
Acknowledge that EPC values 1 and 2 have been switched according
to EPC-Select:
ro
IO-Link V1.1 only
0 - EPC-Select = 00
1 - otherwise
ro
IO-Link V1.1, V1.0
Device is working optimally
ro
IO-Link V1.1, V1.0
Device is working but there are warnings
ro
IO-Link V1.1, V1.0
Device is not working properly, there are errors
EPC value 1 (byte)
ro
IO-Link V1.1 only
Holds 8bit value as selected by EPC-Select
(see PD Out Byte 0)
ro
IO-Link V1.1 only
EPC value 2 (word)
Holds 16bit value as selected by EPC-Select
(see PD Out Byte 0)
ro
IO-Link V1.1 only
Access
Availability
wo
IO-Link V1.1, V1.0
Vacuum on/off
wo
IO-Link V1.1, V1.0
Activate Blow-off
Vacuum on/off with continuous suction disabled
wo
IO-Link V1.1, V1.0
(regardless of dCS parameter)
wo
IO-Link V1.1, V1.0
Perform CM Autoset function and save EPC data in buffer
Select the function of EPC values 1 and 2 in PD In
(content is 2 bit binary coded integer)
0:
EPC value 1 = Input pressure (0.1 bar)
EPC value 2 = System vacuum (1 mbar)
1:
EPC value 1 = CM-Warnings (see ISDU 146 for bit definitions)
wo
IO-Link V1.1 only
EPC value 2 = Evacuation time t1 (1 msec)
2:
EPC value 1 = Leakage of last suction cycle (1 mbar/sec)
EPC value 2 = Last measured free-flow vacuum (1 mbar)
3:
EPC value 1 = Primary supply voltage (0.1 Volt)
EPC value 2 = Air consumption of last suction cycle (0.1 NL)
Select Production Profile
(content is 2-bit binary coded integer)
0: Activate Production Setup Profile P0
wo
IO-Link V1.1, V1.0
1: Activate Production Setup Profile P1
2: Activate Production Setup Profile P2
3: Activate Production Setup Profile P3
wo
IO-Link V1.1 only
Pressure value from external sensor (unit: 0.1 bar)
Access
Default value
ro
J. Schmalz GmbH
Manufacturer designation
ro
www.schmalz.com
Internet address
ro
SCPSi_V2
General product name
ro
SCPSi 00 G2 NC M12-5 Order-Code
ro
10.02.02.*
Order-Nr.
ro
00
Article revision
ro
03
Hardware revison
ro
2.01
Firmware revision
ro
000000001
Serial number
rw
***
User string to store location or tooling information
Bit 0:parameter access lock (lock ISDU-write access)
rw
0
Bit 1: data storage lock
Bit 2: local parameterization lock (lock menu editing)
0 = menu editing unlocked
rw
0
>0 = menu editing locked with pin-code
1 of 4
SCPSi series
07.03.2022
IO-Link Version 1.0 (legacy mode)
Remark
Remark
Remark
SCPSi Data Dictionary