The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for the gas
part and with norm 73/23 for the electric part. The installation must be done observing the norms in force particularly
concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
DIMENS
MODEL
cm
CF4-98G
80x 90x90
CF4-98GE
80x 90x90
CF6-912GV
120x 90x90
CF6-912GEV 120x 90x90
CF6-912GE
120x 90x90
CF8-916GEV 160x 90x90
CF8-916GE
160x 90x90
PC-94G
40x 90x90
PC-98G
80x 90x90
PC-912G
120x 90x90
PC-916G
160x 90x90
PCT-94G
40x 90x29
PCT-98G
80x 90x29
PCT-912G
120x 90x29
PCT-916G
160x 90x29
CF6-912G
120x 90x90
CF8-916GV
160x 90x90
CF8-916G
160x 90x90
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Ensure that the air outlets in the place of work are sufficient to guarantee the necessary air exchange, as stated in
paragraph 4.3 of the UNI-CIG. norm 8723.
The appliance may be installed as a single element or in series with other appliances of our production. It is necessary to
observe a minimum distance of 10 cm from the appliance to prevent contact with walls of inflammable material;
adequate measures must also be taken to ensure thermal insulation of inflammable parts, such as the installation of a
protection against radiation; particular attention must be paid in installing the appliances adequately and safely. The feet
are adjustable in height so that differences in level can be avoided.
We remind you that appliances installed in buildings for public use must meet the following requirements:
In Italy:
1)
Installation regulations
GB
DECLARATION OF COMPLIANCE
TECHNICAL DATA TABLE
NOMINAL BURNER CAPACITY kW
Gas
Gas
4
7
10
oven
oven
GN2/1
GN3/1
1
2
1
8,5
1
2
1
/
1
3
2
8,5
1
3
2
/
1
3
2
/
2
4
2
/
2
4
2
/
1
1
/
/
1
2
1
/
1
3
2
/
2
4
2
/
1
1
/
/
1
2
1
/
1
3
2
/
2
4
2
/
1
3
2
/
2
4
2
/
2
4
2
2x8,5
INSTALLATION
CHECKING FOR CORRECT VENTILATION
IE
IT
CH
TOT. NOM.
CAPACITY
kW
Electric
Gas
Elect
oven
/
/
36,5
/
6,7
28
/
/
53,5
/
6,7
45
/
9,2
45
/
9,2
56
/
6,7+6,7
56
/
/
11
/
/
28
/
/
45
/
/
56
/
/
11
/
/
28
/
/
45
/
/
56
13
58
/
13
/
69
/
/
73
31
Gas
MAX.
coupling
ABSORB
ISOR7
A
/
R 3/4"
6,7
R 3/4"
10
/
R 3/4"
6,7
R 3/4"
10
9,2
R 3/4"
14
9,2
R 3/4"
14
13,4
R 3/4"
20
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
/
R 3/4"
POWER
SUPPLY
CABLE
mm²
5x1
5x1
5x1,5
5x1,5
5x2,5