Grounding Instructions
Warning
To avoid the risk of electrical shock or death,
this equipment must be grounded.
Warning
To avoid the risk of electrical shock or death, do not
alter the plug.
This equipment MUST be grounded. In the event of an
electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. This oven is equipped with a cord having a
grounding wire with a grounding plug. The plug must be
plugged into an outlet that is properly installed and
grounded.
Consult a qualified electrician or servicer if grounding
instructions are not completely understood, or if doubt
exists as to whether the equipment is properly grounded.
Do not use an extension cord. If the product power cord
is too short, have a qualified electrician install a three-slot
receptacle. This oven should be plugged into a separate
60 hertz circuit with the electrical rating as shown in the
appropriate drawing. Models MM2000C* and CMM2000C*
require a 208 volt supply voltage. Models MM2230C* and
CMM2230C* require a 230 volt supply voltage. When a
microwave oven is on a circuit with other equipment, an
increase in cooking times may be required and fuses can
be blown.
NEMA 6-20R
250V–20AMP
CMA2000*
CMA2230*
6-30R
NEMA 6-30R
250V–30AMP
CCMA2000
CCMA2230
6
Installation
Unpacking Equipment
• Remove packing and printed material from oven
cavity.
• Report any dents or breakage to source of
purchase immediately.
• Inspect equipment for damage such as dents in
door or inside oven cavity.
Equipment Placement
• Do not install equipment over or under another
microwave, convection, or combination oven.
• Do not install equipment next to or above source of
heat, such as pizza oven or deep fat fryer.
Excessive heat may cause equipment to operate
improperly and shorten life of electrical parts.
• Install combination oven so oven bottom is at least
91.5 centimeters / 3 feet above floor.
• Allow air flow around equipment. Leave at least
3.18 centimeters / 1¼ inch between air discharge
on back of equipment and back wall. Lift handle on
back of equipment ensures 3.18 centimeters / 1¼
inch spacing. Restricted airflow may cause
equipment to operate improperly and shorten life of
electrical parts.
• Install according to all local building codes and
ordinances.
Radio Interference
Microwave or combination mode operation may cause
interference to radio, television, or similar equipment.
Reduce or eliminate interference by doing the following:
• Clean door and sealing surfaces of oven according
to instructions in Care and Cleaning section.
• Place radio, television, etc. as far as possible from
equipment.
• Use a properly installed antenna on radio,
television, etc. to obtain stronger signal reception.