30
5.4
NON-COMBUSTIBLE FACING MATERIAL
EN
WARNING: Non-combustible facing material must not project more than 1" (24.5mm) from the face of the door
(all four sides). If greater projections are desired, increase the clearance to the sides and top by 2" (50.8mm)
for every additional 1" (25.4mm) of projection. If using an optional surround, then 2" (50.8mm) clearance from
the surround is required before projecting out a maximum 2" (50.8mm). If greater projections are desired,
increase the clearance from the surround by 2" (50.8mm) for every 1" (25.4mm) of additional projection.
A
A
6" (152.4mm)
4" (101.6mm)
2" (50.8mm)
OPTIONAL
SURROUND
W415-1150 / 02.28.13
4"
(101.6mm)
3" (76.2mm)
2" (50.8mm)
TOP OF
APPLIANCE
0" (0mm)
DOOR
SECTION A - A
B
B
6" (152.4mm)
4" (101.6mm)
2" (50.8mm)
0" (0mm)
SECTION B - B
71.5A
4" (101.6mm)
3" (76.2mm)
2" (50.8mm)
1" (25.4mm)
TOP OF
APPLIANCE
DOOR