Installation instructions
Install the continuous-flow heater as described in the il-
lustrated section. Observe the instructions in the text.
Safety information
Risk of electric shock!
Switch off the mains voltage supply immediately if
a fault occurs.
We do not accept liability for damage resulting from
failure to heed these instructions.
The continuous-flow heater may only be connected
and put into operation by a qualified professional.
Never open the appliance without disconnecting the
power supply beforehand.
The statutory regulations of the respective country, as
well as those of the local electricity and water suppliers,
must be adhered to.
The continuous-flow heater is a Class I appliance and
must be connected to the protective earth.
The appliance must be permanently connected to fixed
wiring.
Caution: Earthed water pipes may give the appearance of
a connected protective earth.
To guarantee compliance to relevant safety regulations,
an all-pole separator must be fitted during installation.
The contact opening must be at least 3 mm.
The continuous-flow heater is only suitable for closed
(pressurized) operation.
The tap and outlet fittings must be approved for operation
with closed (pressurized) continuous-flow heater systems.
The continuous-flow heater can be operated with cold or
pre-warmed water (for example, from a solar energy unit
water supply). Observe the technical data and the special
accessories for this purpose.
The continuous-flow heater is only suitable for connection
to DVGW (German Technical and Scientific Association for
Gas and Water) approved plastic pipes.
The continuous-flow heater may only be installed in a
frost-free room.
Disconnect the electrical connection cable from the
supply and shut off the water supply before connect-
ing the appliance!
Connect the water supply and then connect the elec-
trical supply.
Only make the openings which are required for instal-
lation on the rear of the appliance. If the appliance is
reinstalled, the unused openings must be provided with
watertight sealing.
Do not touch electrically live parts after installation.
10
en
Installation
Unpacking/Removing the cover
I.
Unpack the appliance and check for transport-related
damage.
Please dispose of the packaging, and if applicable, the old
appliance in an environmentally-friendly manner.
Preparations for installation
II.
Important: Only use the supplied installation set.
The supplied water connection nozzles must be installed!
Shut off water supply. The electrical connection (connec-
tion cable) must be disconnected from the power supply.
Unscrew the fuse or switch off the circuit breaker.
Wall mounting
III.
The continuous-flow heater must be mounted on the
wall. Attach it if necessary on the lower adjustable screws.
The distance to the wall is variable. You can compensate
for any unevenness of the wall's surface.
The grommet must tightly surround the connection cable.
If it is damaged during mounting, the openings must be
provided with watertight sealing.
Water connection
IV.
The continuous-flow heater must be vented. Open the
warm water tap fully and flush out the appliance thor-
oughly for 1 minute.
Electrical connection/Mounting
V.
The electrical supply terminal can be fitted at the top or
bottom. The sheath of the connection cable must extend
for at least 40 mm into the appliance.
Startup/additional information
VI.
Remove the flow-rate limiter (see Fig. A) with low water
pressure.
Explain the operation of the continuous-flow heater to
the user.
If the continuous-flow heater does not have sufficient
A
water flow due to low water line pressure in your do-
mestic plumbing system, remove the flow-rate
limiter.
Priority circuit for the combination with electrical stor-
B
age heaters:
For operation with a priority circuit, a special load
shedding relay BZ 45L20 (special accessory) is re-
quired. Other existing load shedding relays, with the
exception of electronic load shedding relays, may
malfunction.
The control electronics must be coded when operated
C
with a load shedding relay.
The filter upstream from the check valve in the cold
D
water supply inlet is clogged.
Remove the filter and either clean it or descale it.
See Figure D 1–3.