This unit is equipped with a Vacuum Shut Down Switch (Part CU-VS), which help control various
functions of the unit. If an operational error occurs in the unit, a switch will either stop the top (feed)
auger or shut the unit off; if the unit turns off an E-1 Code (error code) will appear in the Heat Range
and Blower Speed windows of the Control Board. Situations which could cause this include power
failure, Combustion Blower failure, improper flue installation, a blocked flue (from rodents, nests,
etc.), or "dirty burning" from burning improper fuel (see "Important Information" at the beginning of the
manual).
NOTE: The "door ajar" vacuum switch port must be kept clean, or the top auger will
cease to function. Locate the port hole to the right of the burn pot and, with the stove
unplugged and cooled down, use a brush or pipe cleaner (not a vacuum) to keep this
port clear of ash or other debris (see picture).
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
19
Vacuum Switch
"Door Ajar" Vacuum Switch Port
Port is located to the right
of the burn pot