Electrical version and electrical data
Connection voltage
Frequency
Total amps.
Max. fuse (time delay fuse)
Minimum circuit ampacity
Connection voltage
Frequency
Total amps.
Max. fuse (time delay fuse)
Minimum circuit ampacity
Connection voltage
Frequency
Total amps.
Max. fuse (time delay fuse)
Minimum circuit ampacity
Miele recommends connecting the machine via a wall socket with an all-pole means of deactivation and interlock.
The wall socket or isolator must remain accessible at all times once the machine has been installed.
To increase safety, Miele recommends installation of a residual current device (RCD). Only use residual current devices that are sensi-
tive to universal current (type B).
Connection for equipotential bonding
Connection with male thread (machine)
Size of washers and nuts
An equipotential bond with good contact connection must always be provided in accordance with all national and local regulations.
Water connections
Cold water connection
Required flow pressure
Maximum flow rate (if no hot water and hard water supply)
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied
*With liquid dispensing
Hot water connection EL
Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied
en - Technical details
208/240 V   3 Ph
440/480 V   3 Ph
240 V   1 Ph 3 Wire
3/8" x 1 3/16" (10 mm x 30 mm)
14.5-145 psi (1–10 bar)
19.5 (21*) gpm / 74 (79.5*) l/min
6.8 (8.3*) gpm / 26 (31.5*) l/min
2 (3*) x 61" (1550 mm)
14.5-145 psi (1–10 bar)
4.5 gpm (16 l/min)
1 x 61" (1550 mm)
60 Hz
63 A
70 A
63 A
60 Hz
30.4 A
35 A
30.4 A
60 Hz
27 A
30 A
27 A
M 10
3/4"
158°F (70°C)
3/4"
15