8
1
Figure 2: Schematic diagram of installation
1.
Sauna heater
2.
Control panel
3.
Sensor
4.
External on/off switch (option, door contact needed for function)
5.
Door contact (option)
Positioning the heater - normal installation
DANGER! No more than one heater may be
installed in the same sauna cabin.
Position the sauna heater:
on the same wall as the door (or the side wall, if very close
to the door wall). The heater may also be placed in a recess
(see Figure 5).
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 3).
Position the sensor according the picture (see Figure 3).
2
1
5
3
Figure 3: Positioning the heater - normal installation
1.
Minimum distance from the side wall: 120 mm
2.
Sensor position alt 1: 700 mm from the heater
3.
Sensor
4.
Minimum distance from the back wall: 120 mm
5.
Sensor position alt 2: 700 mm from the front of the heater
6.
Sensor position: 200 mm from the ceiling
7.
Minimum distance to the ceiling: 1,030 mm
8.
Minimum distance to interior fi ttings: 100 mm
9.
Minimum ceiling height: 1,900 mm
10. Minimum distance: 20 mm
11. Minimum distance to interior fi ttings: 120 mm
3
4
5
2
6
4
3
7
8
9
11
10
If the wall on which the sensor is to be installed is made of highly
heat-absorbing material (e.g. concrete, brick, etc.), or of hardened
glass, the sensor may be installed in the ceiling at a distance from
the heater, according to Figure 4.
1
1
Figure 4: Ceiling installation of the sensor
1.
1,200 mm
Positioning the heater - recess installation
To position the sauna heater in a recess:
1.
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 5).
2.
Position the sensor according the picture (see Figure 5).
1
1
4
2
Figure 5: Positioning the heater - recess installation
1.
Minimum distance to the side wall: 120 mm
2.
Sensor
3.
Max. 1,000 mm
4.
Sensor position: 700 mm from the front of the heater
5.
Sensor position: 200 mm from the ceiling
6.
Minimum distance to the ceiling: 1,030 mm
7.
Minimum distance to interior fi ttings: 100 mm
8.
Minimum ceiling height: 1,900 mm
9.
Minimum distance: 20 mm
10. Minimum distance to interior fi ttings: 120 mm
1
5
6
7
3
8
10
9