BA TUBELED_40 II
5 | Connection
Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.
The LED light can be controlled using 3 different operating modes, which can be selected as desired. Only an electrician
may install the luminaire because the wire cross sections of the connecting cables must fit in the prescribed standard for
your country. The luminaire is electrically prepared for all 3 following modes.
PIN assignment of the M12 connector is as follows:
Mode 1
PIN 1
= 24V DC
PIN 2
= not used
PIN 3
= GND
PIN 4
= not used
PIN 5
= not used
The luminaire can only be switched ON and OFF by switching the supply voltage at PIN 1.
Mode 2
PIN 1
= not used
PIN 2
= not used
PIN 3
= GND
PIN 4
= 24V DC
PIN 5
= not used
The luminaire can only be switched ON and OFF by switching the supply voltage at PIN 4.
When mounting the luminaire, make sure that the luminaire is fastened securely and
stably. If the luminaire falls down, its weight poses a risk of injury!
Schematic drawing of M12 plug
Possible variants of the M12 connector
PIN 1
Light
PIN 4
Light
Voltage at PIN
Action luminaire
Voltage at PIN
Action luminaire
www.led2work.com | shop.led2work.com
| 11