Command: Save (S)
Command description: Saves data or settings in the control module.
Format:
<STX><ADR>S<SUBCOMMAND><INDEX><DATA><CRC><EOT>
Command: Command (C)
Command description: Control command for the transponder reader (e.g. switching
on relay).
Format:
<STX><ADR>C<SUBCOMMAND><DATA><CRC><EOT>
d) Command Sub-Groups for Command „Load" (L) and „Save" (S)
Parameter 16bit (P)
Command description: Configuration of the transponder reader with a 16bit parameter.
Bits 8 to 15 are currently not in use, but 16 bits mus alwayst be sent as data.
Format:
<STX><ADR>LP<INDEX><CRC><EOT>
<STX><ADR>SP<INDEX><DATA><CRC><EOT>
Index 0000 reader configuration:
Bit
Value 1
7
enable
6
enable
5
enable
4
enable
3
in/out
2
enable
1
enable
0
on/off
Value 0
Configuration
disable
Send Event
disable
Button recognition (transponder „0")
disable
Activate button for „Switching off relay"
disable
Switch relay
Minute
Storage mode
disable
Save unauthorised access
disable
Auto off / Retrigger
Impulse
On/Off or impulse mode
61