Télécharger Imprimer la page

Continental Fireplaces CA36 Serie Manuel D'installation page 46

Masquer les pouces Voir aussi pour CA36 Serie:

Publicité

Les langues disponibles

Les langues disponibles

finishing
EN
9.9
logo placement
Remove the backing of the logo supplied and place, as illustrated.
9.10 glowing embers
WARNING
!
Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed
ignition.
Tear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be
taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow.
The ember material will only glow when exposed to direct fl ame; however, care should be taken to not
block off the burner ports.
Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. PHAZER™
logs glow when exposed to direct fl ame. Use only certifi ed "glowing embers" and PHAZER™ logs available from
your local authorized dealer / distributor.
9.11 charcoal embers
WARNING
!
Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon
deposits and delayed ignition.
When supplied, charcoal embers, charcoal lumps and vermiculite are not to be placed on the burner.
Randomly place the charcoal embers along the front and sides of the log support in a realistic manner.
Fine dust found in the bottom of the bag should not be used.
note:
Charcoal embers are not to be placed on the burner.
9.12 air shutter adjustment
note:
Adjustment may be required depending on fuel type, vent configuration and altitude.
Fine air adjustments should be made using the lever
to get the desired flame (Fig. 1).
Caution: Before proceeding, the gas supply
must be shut off prior to disconnecting the
electrical power.
note:
It is important that the orifice is securely inserted
into the venturi.
Regardless of venturi orientation, closing the
air shutter will cause a more yellow flame, but can lead to
carbonization. Opening the air shutter will cause a more blue flame,
but can cause flame lifting from the burner ports. The flame may
not appear yellow immediately; allow 15 to 30 minutes for the final
flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A
QUALIFIED INSTALLER!
46
W415-2026 / B / 04.27.23
Air Shutter
Opening
Some components
hidden for clarity.
1/2"(12.7mm)
INSERT
LOGO
IMAGE
1/2"(12.7mm)
HERE
45.5
22.1A
22.2
Air Shutter Lever
(push up to close,
pull down to open)
Fig. 1

Publicité

loading

Ce manuel est également adapté pour:

Ca42 serieCa36nteCa42nteCa36pteCa42pte