rough framing
EN
3.4
minimum framing dimensions
SIDE WALL
C
Horizontal vent sections: A minimum clearance of 3" (76mm) on the top of the vent to combustibles and 2"
(51mm) on the sides and bottom of the vent to combustibles is required.
Vertical vent sections: A minimum clearance of 1" (25mm) all around the vent pipe on all vertical runs to com-
bustibles is required.
B
C
D
E
22
W415-2026 / B / 04.27.23
12"
(30.5cm)
B
Do not put objects in front of the appliance
(minimum distance of 4 feet)*
CA36
36 1/4" (92.1cm)
46 5/16" (117.63cm)
65 1/2" (166.4cm)
E
CA42
43 1/4" (109.8cm)
19" (48.2cm)
51 1/4" (130.2cm)
72 1/2" (184.2cm)