finishing
EN
9.7
minimum combustible mantel clearances
Combustible mantel clearances vary according to the mantel depth. Use the graph to help evaluate the clearance
needed.
26
24
22
20
M
H
18
A
E
16
N
I
14
T
G
12
E
H
10
L
T
8
6
4
0
1 2
3 4
MANTEL DEPTH
MANTEL DIMENSIONS
Ref
J
10" (254mm)
K
12" (30.5cm)
L
14" (35.6cm)
M
16" (40.6cm)
ONLY if the Universal Heat Management System is installed, mantel
clearances can be reduced.
24
22
20
18
M
H
16
A
E
14
N
I
12
T
G
10
E
H
8
L
T
6
4
2
0
12 14 16 18 20 22 24 26 28 30 32
WARNING
!
Risk of fire! Reduced mantel clearances are ONLY acceptable for applications with UHM installed.
*Mantel depth must be appropriately sized if placing any valuable items above the fireplace / mantel (see
"clearances around appliance (TV and valuable objects)").
44
W415-2026 / B / 04.27.23
E
D
C B
5 6
7
8
9
10
Height
Depth*
A
2" (51mm)
4" (102mm)
6" (152mm)
8" (203mm)
MANTEL DEPTH
A
BOTTOM OF
APPLIANCE
MANTEL DIMENSIONS (WITH UHM)
Ref
B
J
K
L
4" (10.2cm)
6" (15.2cm)
M
M
L
K
J
TOP OF
FIREPLACE
OPENING
CA36 = 33 1/16"
CA42 = 36 1/16"
Height
Depth*
0"
12" (30.5cm)
2" (5.0cm)
14" (35.5cm)
16" (40.6cm)
18" (45.7cm)