Conversion from LP Gas to Natural
Installation of the regulator
1.
Turn off all burner control valves.
2.
Turn off the main gas supply valve.
3.
Disconnect 9 kg (20 lb) LP gas fuel tank (if present) and
remove the 9 kg (20 lb) LP gas fuel tank from the grill
cabinet.
4.
Use an adjustable wrench to remove the LP gas pressure
regulator/hose assembly from the 90º brass adapter.
A.
Flexible gas hose from grill
B.
90º brass adapter
C.
LP gas pressure regulator/hose assembly
5.
Use a Phillips screwdriver to remove the 2-piece 90º
clamp mounting bracket from the cabinet wall. Remove
90º brass adaptor.
A.
4 screws
B.
2 piece 90º clamp mounting bracket
C.
90º brass adaptor
Gas
A
B
A
6.
Install the Natural gas pressure regulator onto the flexible
gas hose from the grill.
7.
Check that the Natural gas pressure regulator is
positioned under the grill (as shown in the following
illustration) and that the hose is not pinched or kinked.
Use 4 screws to attach the Natural gas pressure regulator
to the back of the enclosure.
C
A.
Natural gas pressure regulator
Four 5/32-32 x 3/8" truss head screws (type "A" from the
B.
hardware packet)
Four 5/32" flat washers (type "B" from the hardware packet)
C.
B
C