Turn the Gas Supply On
1.
For outdoor grills using a 9 kg (20 lb) LP gas fuel tank:
Slowly open the tank valve.
NOTE: If flow limiting device activates, your grill may not
light. If your grill does light, the flames will be low and will
not heat properly. Turn tank valve and all control knobs off
and wait 30 seconds. After shutting off the tank, very
slowly open tank valve and wait 5 seconds before lighting.
2.
For outdoor grills using gas supply source other than a 9
kg (20 lb) LP gas fuel tank:
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
Lighting the Grill Burners
IMPORTANT: If burner does not light immediately, turn the
burner knob to "○" and wait 5 minutes before relighting.
1.
Open the hood completely. Do not light burners with the
hood closed.
2.
Do not lean over the grill.
3.
Select the burner you want to light. Push in and turn the
grill burner control knob to "
in.
You will hear the "snapping" sound of the spark. When
4.
burner is lit, release the knob. Turn knob to desired setting.
5.
Repeat for each of the other burners as needed.
", while continuing to hold it
Manually Lighting Grill Burners
1.
Open the hood completely. Do not light burners with hood
closed.
2.
Do not lean over the grill.
3.
Remove the manual lighting extension (see following
illustration) and attach a match to the split ring.
4.
Strike the match to light it.
5.
Guide the lit match under the grill grate.
Push in and turn the burner knob to "
6.
closest to the lit match. The burner will light immediately.
When burner is lit, turn knob to desired setting.
7.
Repeat steps 2 trough 6 for each main burner.
8.
Remove match and replace manual lighting extension on
the right side panel.
IMPORTANT:
If burner does not light immediately, turn the burner knob to "○"
and wait 5 minutes before relighting.
If any burners do not light after attempting to light them
manually, contact the Customer Service Center. See the
"Assistance" section.