(2) Current
Function
Range
99.99A
ACA
599.9A/999.9A*
0.10A ~ 99.99A
HFR
ACA
599.9A/999.9A*
* 3515F : 599.9A ; 137F : 999.9A
** The measured value <1000dgt, add 5 dgt to the accuracy.
3525F,3535F
Function
Range
99.99A
DCA
599.9A/999.9A*
0.10A ~ 99.99A
ACA
599.9A/999.9A*
0.10A ~ 99.99A
HFR
ACA
599.9A/999.9A*
* 3525F : 599.9A ; 3535F : 999.9A
** The measured value <1000dgt, add 5 dgt to the accuracy.
Overload protection : 1000A
600A
Position Error : ±1% of reading.
AC Conversion Type and additional accuracy is same as AC
Voltage.
AC+DC Arms Accuracy : Same as ACA spec + DCA spec.
- For better measurement accuracy of high current and the
constraint of temperature increasing of maximum range
600A/1000A AC, do not measurement more than 10min. and
have rest time with 30min. at least in between every measure-
ment (for 3515F).
- DCA affected by the temperature and the residual magnetism.
Press HOLD key > 2sec to compensate it.
3515F
Accuracy
50 ~ 60Hz ± (1.5% + 5dgt) **
>60 ~ 400Hz ± (2% + 5dgt) **
50 ~ 60Hz ± (1.5% + 5dgt) **
>60 ~ 400Hz ± (5% + 5dgt) **
Accuracy
± (1.5% + 0.2A)
± (1.5% + 5dgt) **
50 ~ 60Hz ± (1.5% + 5dgt)
>60 ~ 400Hz ± (2% + 5dgt)
50 ~ 60Hz ± (1.5% + 5dgt) **
>60 ~ 400Hz ± (5% + 5dgt) **
For 3535F
rms
For 3515F,3525F
rms
M35X3F M00