INSTALLATION
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT
CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE,
AS WELL AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the
floor.
Exhaust
Pipe
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME / TRANSPORTABLE BUILDING
FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
WHEN INSTALLED IN A MOBILE HOME /
TRANSPORTABLE
MUST BE GROUNDED DIRECTLY TO THE STEEL
CHASSIS AND BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements,
mobile
building installations must meet the following
requirements:
• This stove must be securely fastened to the floor
of the mobile home / transportable building
through the two holes in the rear of the stove
using 2, 1/4" lag bolts that are long enough to go
through both a hearth pad, if used, and the floor
of the home.
• The heater must be electrically grounded to the
steel chassis of the mobile home / transportable
building with 8 GA copper wire using a serrated
or star washer to penetrate paint or protective
coating to ensure grounding.
• Vent must be 3 or 4-inch "PL" Vent and must
extend a minimum or 36" (914 mm) above the roof
Fresh Air
Intake
BUILDING,
THE
STOVE
home
/
transportable
line of the mobile home / transportable building
and must be installed using a certified ceiling fire
stop and rain cap.
• When moving your mobile home / transportable
building, all exterior venting must be removed
while the mobile home / transportable building is
being relocated. After relocation, all venting must
be reinstalled and securely fastened.
• Outside Air is mandatory for mobile home /
transportable building installation. See Outside
Air Supply section and your dealer for purchasing.
• Check with your local building officials as other
codes may apply.
VENTING REQUIREMENTS
• INSTALL VENT AT CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
• DO NOT CONNECT THE PELLET VENT TO A
VENT SERVING ANY OTHER APPLIANCE OR
STOVE.
• DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
The following installation guidelines must be
followed to ensure conformity with both the safety
listing of this stove and to local building codes. Do
not use makeshift methods or compromise in the
installation.
THIS UNIT IS EQUIPPED WITH A NEGATIVE
DRAFT SYSTEM THAT PULLS AIR THROUGH
THE BURN POT AND PUSHES THE EXHAUST
OUT OF THE DWELLING. IF THIS UNIT IS
CONNECTED TO A FLUE SYSTEM OTHER THAN
THE WAY EXPLAINED IN THIS MANUAL, IT
WILL NOT FUNCTION PROPERLY.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical
pipe outside the home. This will create some natural
draft to reduce the possibility of smoke or odor
during appliance shutdown and keep exhaust from
causing a nuisance or hazard by exposing people
or shrubs to high temperatures. The maximum
recommend vertical venting height is 12-feet for
3-inch type "PL" vent. Total length of horizontal
vent must not exceed 4-feet. This could cause back
7