FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
This heater must have a non-combustible floor
protector (UL1618 ember protection) installed
beneath it if the floor is of combustible material.
USA- The floor protector should be listed to UL 1618
or equivalent to type 1 ember floor protection. The
floor protection must extend 6" (153mm) to the
front, 6" (153mm) on each side and 1" to the rear of
the appliance. Under and 2" (51mm) beyond each
side of cleanout tee if indoor vertical installation.
See diagram for further information
Canada - Floor protector must comply with CAN/
ULC standards. Must extend 18" (458mm) forward
and 8" (204mm) beyond each side of unit.
A
Back to Stove
B
Side to Stove
C
Front to Stove
D Back to Flue
CLEARANCES
Your pellet stove has been tested and listed
for installation in residential, mobile home /
transportable building in accordance with the
clearances given below. For safety reasons, please
© 2023 United States Stove Company
U.S.A
1"
26 mm
CAN
8"
204 mm
U.S.A
6"
153 mm
CAN
8"
204 mm
U.S.A
6"
153 mm
CAN
18"
458 mm
2"
51 mm
INSTALLATION
adhere to the installation clearances and restrictions.
Any reduction in clearance to combustibles may
only be done by means approved by a regulatory
authority.
E
Side Wall to Stove
F
Side Wall to PL Vent Pipe
G
Back Wall to Stove
Back Wall to PL Vent
H
Pipe
J
Ceiling to Floor
K
Ceiling to Stove
L
Wall to Stove
M
Side Wall to PL Vent Pipe
N
Wall to PL Vent Pipe
OUTSIDE AIR SUPPLY
INSTALLING IN A MOBILE HOME / TRANSPORTABLE
BUILDING)
Depending
on
your
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home / transportable
building. You can purchase the 69FAK through your
heater dealer. Installation instructions are supplied
with the air intake kit.
6
8"
204 mm
10"
254 mm
9.25"
235 mm
3"
76 mm
60"
1524 mm
27.5
699 mm
7-1/2"
191 mm
11-1/4"
286 mm
7-1/2"
191 mm
(OPTIONAL, UNLESS
location
and
home