DAMPER CONTROL
The damper control lever is located on the back of
the stove on the lower left side. The default setting
for the damper control should be full open. The
damper adjusts the combustion air. This control
is necessary due to the varied burn characteristics
of individual installations, different pellet brands
and pellet feed rates. It allows you to improve
the efficiency of your stove. Providing correct
combustion air will reduce the frequency of cleaning
your glass door and prevent the rapid buildup of
creosote inside your stove and chimney. You should
adjust the damper based on the fire's appearance.
A low, reddish, dirty fire can be improved by turning
the damper slightly to the right. A "blow torch" fire
can be improved by turning the dampener to the
left a little bit. For optimal burning results, refer to
"Optimal Operation" section of this manual.
© 2023 United States Stove Company
OPERATION INSTRUCTIONS
OPENING DOOR
• DO NOT OPERATE YOUR STOVE WITH
THE VIEWING DOOR OPEN. THE AUGER
WILL NOT FEED PELLETS UNDER THESE
CIRCUMSTANCES AND A SAFETY CONCERN
MAY ARISE FROM SPARKS OR FUMES
ENTERING THE ROOM.
• THE FEED DOOR MUST BE CLOSED AND
SEALED DURING OPERATION.
If the door is opened while the stove is in operation
it must be closed within 30 seconds or the stove
will shut down. If the stove shuts down push the
"On/Off" button to re-start your stove. The stove will
have to fully shut down and turn off before you will
be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not
come on until the stove's heat exchanger warms up.
This usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers
will run until the stove cools. This will take 30 minutes
or longer depending on the heat remaining in
the appliance. After the stove components stop
running all lights on the display will go out and the
two digit display will begin flashing "E3"
REFUELLING
• THE HOPPER AND STOVE TOP WILL BE
HOT
DURING
YOU SHOULD ALWAYS USE SOME TYPE
OF HAND PROTECTION WHEN REFUELING
YOUR STOVE.
• DO NOT TOUCH THE HOT SURFACES OF
THE STOVE. EDUCATE ALL CHILDREN ON
THE DANGERS OF A HIGH-TEMPERATURE
STOVE. YOUNG CHILDREN SHOULD BE
SUPERVISED WHEN THEY ARE IN THE SAME
ROOM AS THE STOVE.
• NEVER PLACE YOUR HAND NEAR THE
AUGER WHILE THE STOVE IS IN OPERATION.
• WE
RECOMMEND
HOPPER DROP BELOW 1/4 FULL.
14
CAUTION:
CAUTION:
OPERATION;
THEREFORE,
YOU
NOT
LET
THE