Télécharger Imprimer la page

Ashley AP5613-W Manuel D'instructions Et D'utilisation Du Propriétaire page 21

Publicité

TROUBLESHOOTING GUIDE
Display is Flashing "E2"
Possible Causes
Airflow switch hose or stove attachment
pipes for hose are blocked.
The air inlet, burnpot, interior combustion
air
chambers,
combustion
exhaust pipe are blocked with ash or foreign
material.
The firebox is not properly sealed.
Vent pipe is incorrectly installed.
The airflow switch wire connections are bad.
Combustion blower failure.
Control
board
not
combustion blower.
Control board not sending power to air
switch.
Air switch has failed.
blower,
or
sending
power
to
Possible Remedies: (Unplug stove first when possible)
Unhook air hose from the air switch and blow through it.
If air flows freely, the hose and tube are fine. If air will not
flow throw the hose, use a wire coat hanger to clear the
blockage.
Follow all cleaning procedures in the maintenance section
of the owner's manual.
Make sure the door is closed and that the gasket is in good
shape.
Check to make sure vent pipe installation meets criteria in
owner's manual.
Check the connectors that attach the gray wires to the air
switch.
With the stove on, check to see if the combustion blower is
running. If it is not, you will need to check for power going
to the combustion blower. It should be a full current. If
there is power, the blower is bad. If there is not, make sure
the control board is sending power to the air switch.
If there is no current going to the combustion blower, check
all wire connections. If all wires are properly connected,
you have a bad control board.
There should be a 5-volt current (approximately) going to
the air switch after the stove has been on for 30 seconds.
To test the air switch, you will need to disconnect the air
hose from the body of the stove. With the other end still
attached to the air switch, very gently suck on the loose end
of the hose (you may want to remove the hose entirely off
the stove and the air switch first and make sure it is clear).
If you hear a click, the air switch is working. BE CAREFUL
TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH.
21
© 2023 United States Stove Company

Publicité

loading