Type
Nominal performance
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
CO (relating to 13% O²)
dust (relating to 13% O²)
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions
3.2 Dimension
Art. Nr.
(mm)
RIVA
W20001018181*
1080 672
G001018182 - 87
RONA Kachel
W20001018130*
1216
G001018131 - 32
1236
G001050170 / 75
W20001050190*
*
Basic equipment without ceramics
The specified dimensions and weights are approximate values, and thus have only informative
purposes. We reserve the right to modify the designs as required in terms of technology or quality!
3
)
fuel:
A
B
C
(mm)
(mm)
(mm)
890
990
-
-
890
990
820
295
1070
860
300
1070
-
-
412
-
-
392
TYP11181
6 kW
116
69
47
wood / brown coal
6,2 / 7,2 g/s
268 / 271°C
12 Pa
≤ 40 mg/m³
1032 / 769 mg/Nm
82 / 79,7 %
D
E
F
(mm)
(mm)
(mm)
-
-
561
137
1173
375
330
1173
395
350
-
-
-
350
-
-
-
330
34
TYP10181
8 kW
182
105
71
wood / brown coal
7,9 / 8,6 g/s
295 / 316°C
12 Pa
≤ 40 mg/m³
3
1078 / 729 mg/Nm
80,3 / 78,6 %
G
H
I
(mm)
(mm)
(mm)
-
-
-
-
-
-
625
130
655
130
-
-
361
-
-
341
3
J
*weight
netto
-
90
-
161
-
101
-
165
9
3