Télécharger Imprimer la page

American Standard Flash RU101 Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

1
STANDARD WALL INSTALLATION
Turn off hot and cold water
CAUTION
supplies before beginning.
n
See Roughing-in diagram before starting.
Remove the PLASTER GUARD (8) for proper installation.
n
n
Mount VALVE BODY to cross brace (2" X 4") with-in wall. Use wood screws to secure VALVE BODY to brace.
Connect HOT and COLD water supplies per connection method of selected valve.
n
Connect RISER PIPE (1) to VALVE BODY (2) top outlet marked "UP".
n
Connect TUB FILLER PIPE (3) to bottom outlet.
n
Install PLASTER GUARD (8) back onto the valve. Only remove PLASTER GUARD (8) when ready to install trim Kit.
n
n
Finished wall should allow for a 4" diameter opening (Use PLASTER GUARD for guidance)
CAUTION: After valve installation, inspect the VALVE BODY for any debris. It can damage Pressure Balance
Valve cartridge.
NOTE: For back to back installation, follow steps mentioned above. Reversal of Hot/Cold water supplies is
accomplished by rotating cartridge (supplied with trim) 180° during installation.
NOTE: TO AVOID SHOWER RISE OR
OTHER RELATED ISSUES, DO NOT
USE PEX CONNECTIONS AT THE TUB
OUTLET CONNECTING TO THE TUB
SPOUT.
CROSS BRACE
1
2
6
COLD
HOT
3
WOOD
SCREWS
8
- 2 -
SIDE VIEW
3-1/2"
(100 mm)
7/8" TO 2"
(22 mm to
50 mm)
2 x 4
Cross
Brace
2-3/4" MAX.
(69 mm)
1-3/4" MIN.
(45 mm)
M965906 Rev. 1.2 (8/19)
4"
(101 mm)

Publicité

loading