Télécharger Imprimer la page

Elica PUCFS130SS Instructions D'installation page 9

Publicité

Les langues disponibles

Les langues disponibles

1. Remove the 3.2" x 10" (8.3 x 25.4 cm) rectangular vent
connector attached with screws or taped on the inside your
range hood.
NOTE: Some models are recirculation (non-ducted only) and will
not have vent connector.
A. Screws
B. 3.2 "X 10" (8.3 X 24.4 cm)
rectangular vent connector
2. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
A. Keyhole slot
3. Use .11" (3 mm) drill bit and drill 4 pilot holes as shown.
A. Drill pilot hole
4. Install the 4 - 4.5 mm x 13 mm mounting screws in pilot
holes. Leave about .25" (6.4 mm) space between screw heads
and cabinet to slide range hood into place.
B
A
A
"
(6.4 mm)
5. Remove transition knockouts depending on your model.
A. Round vent knockout
B. Top rectangular vent knockout
C. Rear rectangular vent knockout
Round vent system installations - Remove top rectangular
and round vent knockouts.
Rectangular vent system installations - For roof
installations, remove the top rectangular vent knockout. For
wall installations, remove the rear rectangular vent knockout
Non-ducted (recirculating) installations - Do not remove
any knockouts.
5. Remove metal grease filters. See the "Range Hood Care"
section.
6. For round installation: Install 7" (17.8 cm) round vent mounting
plate and damper or 3.25" x 10" (8.3 x 25.4 cm) vent
connector, depending on your vent system installation.
9
A
B
C

Publicité

loading

Ce manuel est également adapté pour:

Pucfs130bl