Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
C
A
B
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
2. Use UL listed wire connectors and connect white wires (A)
together.
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Connect green (or bare) ground wire from power supply to
green ground screw in terminal box. Be sure the ground wire
is secured and the screw is well tight.
5. Install terminal box cover.
6. Reconnect power.
Control and features:
Operating the lights x3
Push the light switch to the left to turn the light Off. Push the light switch to the right
to the turn the light On.
Operating the fan
Push the fan switch to the left for Low speed. Push the fan switch to the right for
High speed. Push the fan switch to the middle for Off.
G
E
D
F
E. Home power supply cable
F. UL listed or CSA approved
½" strain relief
G. Green ground screw
RANGE HOOD CONTROL
WARNING
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Complete Installation
7. Install the 75 W (max.) incandescent light bulb. See
Range Hood Care section.
8. Replace grease filter if removed. See the "Range Hood Care"
section.
9. Check the operation of the range hood fan and light. See
"Range Hood Control" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Control" section.