OPERATION
TLC
5
1
4
2
3
1: + motor
2: On/Off motor
3: - motor
4: On/Off light
5: Led
Note: the LED on the hood indicates the various speeds: green 1st speed, orange 2nd speed, red 3rd speed and flashing red 4th speed.
All hoods with capacities exceeding 650 m3/h have the last timed speed; It lasts for 7 minutes, after which it
automatically returns to the last non-timed speed.
Initialization procedure:
1. Cut off power to the hood
2. Power the hood again
3.Within the first 5 sec, press the light button and release it after the lights turn on (the control must be turned on via key 3)
4. Within 5 sec, press the motor key and release it
Now you have to wait for about 10 seconds – then you can use the hood normally.
Notes: after 4 hours from the last use of a key, the hood turns off automatically.
Should there be interferences with other nearby remote controls, carry out the code change procedure.
Should it be required to replace the radio control, the frequency of the electronic system of the new radio control must be calibrated
again via the initialization procedure.
Procedure for generating a new code for the radio control.
The radio control is supplied with default codes. If you want to generate new random codes you need to follow the procedure below:
simultaneously press the plus and minus keys for at least 10 seconds; the LED will turn on, then press the two buttons again (within
3 seconds). The LED flashes three times to indicate that the operation has been completed. Once you changed the radio control you