Télécharger Imprimer la page

Franke AQRM650 Notice De Montage Et De Mise En Service page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10. Assembly
Warning!
Only operate the fitting with non-return valves and the specified filters.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
Important!
Prior to the assembly process, flush the pipework in accordance with DIN 1988.
10.1 Install the screw connections (a).
10.2 Install the screw rosettes (b).
10.3 Install the outlet screw connection (c) with the rosette (d).
10.4 Insert the filters (e).
10.5 Install the fitting (g) with union nuts (f).
10.6 Attach the outlet bend (h) to the fitting.
10.7 Open the water volume regulators (i).
10.8 Check the water connections for leaks.
11. Function
Trigger the flow of water
11.1 Press the pressure cap.
• The water will flow.
• The water flow stops automatically once the preset flow time has expired.
The flow time is adjustable from 1-50 seconds.
Temperature selection
12. Adjusting the flow time
12.1 Using a screwdriver, carefully take off the stopper.
12.2 Remove the stopper.
12.3 Release the grub screw with an Allen key.
12.4 Remove the pressure cap.
12.5 Use a screwdriver to set the flow time.
a: Blade width 3 mm
+ longer flow time (max. 50 s)
– shorter flow time (min. 1 s)
12.6 Trigger the fitting to measure the flow time.
6
info@hygiene-shop.eu - www.hygiene-shop.eu

Publicité

loading

Ce manuel est également adapté pour:

Aqrm27420000900252000101037