GB
1. TECHNICAL DATA
Power supply
Absorption
Geared motor torque
Max. door weight
Service class
Intermittence
Max. shutter width
Speed
Temperature
Degree of protection
Control panel
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be guar-
anteed with the use of DITEC accessories and safety devices.
2.1 Standard installation references (fi g. 1)
[1]
Radio (BIXLP2)
[2]
Electrical board
[3]
Key selector
[4]
Geared motor
[5]
Photocells
[6]
Dampening rims / Sensitive rims
[7]
Release cord
[8]
Connect power supply to a type-approved omnipolar
switch with a contact opening gap of no less that 3 mm
(not supplied by us).
2.2 Geared motor references (fi g. 2)
[9]
Geared motor
[10] Motor
[11] Release
[12] Wiring clamps
[13] Fixing base
3.
ACCESSOIRES
DORBD Straight arm
DEB04 Key handle with release cord
4.
INSTALLATION
Unless otherwise specifi ed, all measurements are expressed
in millimetres.
4.1 Preliminary checks
Check that the structure is suffi ciently sturdy and that the hinge
pivots are properly lubricated.
4.2 Geared motor installation
-
Select installation mode: geared motor concealed left (Fig.
3) or right (Fig. 4), or geared motor exposed left (Fig. 5)
or right (Fig. 6). To reverse installation of the Dor from left
to right, proceed as shown in Fig. 8.
-
Remove the enclosure and take off the geared motor from
the mounting plate.
-
Secure the mounting plate to the wing according to the
measurements given in fi gs. 7 and 10.
-
Install the geared motor on to the mounting plate.
Attention: The geared motor shaft must always be turned
upwards, facing the hinge between the two wings.
-
With the door open determine the mounting position of the
arm on the wing (see fi gs. 3, 4, 5, and 6).
-
Shorten the tube and if necessary the rod depending on
the previously determined mounting positions (geared
Dor 1B / 1BH / 1BHS - IP1783
Dor 1B
230V~ 50Hz
1.3 A
300 Nm
500 Kg
3 - FREQUENT
S2 = 15 min, S3 = 25%
L max = 1.5 + 1.5 m
1.6 RPM
-20°C / +55°C
IP44
E1F / E2
LOGIC A21F / LOGIC A22
Dor 1BH
24V=
12 A
300 Nm
500 Kg
4 - HEAVY DUTY
S2 = 30 min, S3 = 50%
L max = 1.5 + 1.5 m
2,5 RPM
-20°C / +55°C
IP44
LOGIC C22
motor shaft [E] and wing [C]).
Warning: after the tube has been fi t in all the way, ensure
that it does not knock against the rod's bush or that the
rod's head does not knock against the screw that secures
it to the wing (min. 5 mm).
-
Mount the arm Dor BD and lubricate the rod.
-
Release the geared motor by pulling the cord and secu-
ring it in the release position (see RELEASE INSTRUC-
TION).
-
Perform a manual maneuver to ensure that the movement
is devoid of obstacles or friction and that the arm stays
horizontal.
-
Re-lock the geared motor.
5.
ELECTRICAL CONNECTION
The power connections are shown in fi gures 11,12,13,14.
Start-up and adjustments are described in the E1F, E2,
LogicA21F, LogicA22 (DOR1B) - LogicC22 (DOR1BH -
DOR1BHS) electronic panel manual.
6.
MAINTENANCE PROGRAM (each 6 month)
Power off 230 V~:
-
Clean and lubricate the moving components.
-
Check for the stability of the automatism and check that all
the screws are tightened all the way.
Power on 230 V~:
-
Check the good operation of all command and safety func-
tions.
-
Check for the stability of the door and that the movement is
steady, without friction.
ATTENTION: For spare parts, see the spares price list.
All right reserved
All data and specifi cations have been drawn up and checked
with the greatest care. The manufacturer cannot however take
any responsibility for eventual errors, ommisions or incomplete
data due to technical or illustrative purposes.
10
Dor 1BHS
24V=
12 A
300 Nm
500 Kg
4 - HEAVY DUTY
S2 = 30 min, S3 = 50%
L max = 1.5 + 1.5 m
2,5 RPM
-20°C / +55°C
IP55
LOGIC C22